7. Configuration of connectors and terminal blocks
7-1 Power connectors
Size A, B 100 V / 200 V
Pin No.
Symbol
5
L1
4
L2
XA
3
L3
2
L1C
1
L2C
6
P
5
N
XB
4
B
3
U
2
V
1
W
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.
R2.0
XA ,
XB
,
XC
Name
100 V
Main power input
terminal
200 V
100 V
Control power input
terminal
200 V
To use an external regenerative resistor (customer prepared), connect an external
regenerative resistor between P and B.
Regenerative resistor
In addition, parameter setting is required for the regenerative resistor.
connecting terminal
For details, refer to "Technical Refarence - Functional Specification-"
Do not connect anything to the N terminal.
Connect each phase of the motor wiring.
Motor output terminal
U
Earth terminal for grounding
Erath
,
XD and terminal block
Description
Single-phase 100 - 120 V
For single-phase, the connector should be connected to the L1 and L3 terminals.
Single-phase/3 phase 200 - 240 V
For single-phase, the connector should be connected to the L1 and L3 terminals.
Single-phase 100 - 120 V
Single-phase 200 - 240 V
:
:
:
U phase, V
V phase, W
W phase
Industrial Device Solution Business Unit, Panasonic Corporation
No. SX-DSV03335 - 34-
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %