Procedure of connection to the power connector

To connect to Connector
<Wiring method>
1. Stripping electric wires to be used. Please refer to the figure below for the strip length
2.Insert the wire into the connector.
①Push down the spring by
pushing the control lever
attached to the upper
operating slot with your
fingers.
<Notes>
· Be careful not to damage the core wire or cut it when stripping the wire.
· Because the strip length of the electric wire depends on the size and type of electric wire,
please decide the optimum strip length according to the processing condition.
· For wiring, please disconnect the connector from the servo driver main body.
· Insert one wire into one wire insertion slot of the connector.
· When the control lever is pushed down, the wire can be removed.
R2.0
XA
XB
10 mm (Size A
C, Size D 200 V
-
11 mm (Size D 400 V, Size E
8~9 mm
8 mm (Size D
E 400 V
-
②Insert the wire while
pressing the control lever.
Please be careful that all
strands are inserted into the
spring opening
XC
XD , follow the procedure below.
XA
XB
)
XA
XB
XC
)
XD
)
Industrial Device Solution Business Unit, Panasonic Corporation
No. SX-DSV03335 - 63-
③You can wire it by
releasing the control lever.
Please pull the wire lightly
and make sure that the wire
is securely connected.