Size C, D 100 V / 200 V
Pin No.
Symbol
5
L1
4
L2
XA
3
L3
2
L1C
1
L2C
4
N
3
XC
2
P
1
6
P
5
RB
XB
4
B
3
U
2
V
1
W
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.
R2.0
Name
100 V
Main power input
terminal
200 V
100 V
Control power input
terminal
200 V
• Do not connect anything to this connector.
-
To use an external regenerative resistor (customer prepared), connect an external
regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
Regenerative resistor
For details, refer to "Technical Refarence - Functional Specification-"
connecting terminal
Do not connect anything to the N terminal.
Connect each phase of the motor wiring.
Motor output terminal
U
Earth terminal for grounding
Earth
Description
+ 10 %
Single-phase 100 - 120 V
- 15 %
For single-phase, the connector should be connected to the L1 and L3 terminals.
Single-phase/three-phase 200 - 240 V
For single-phase, the connector should be connected to the L1 and L3 terminals.
+ 10 %
Single-phase 100 - 120 V
- 15 %
+ 10 %
Single-phase 200 - 240 V
- 15 %
:
:
:
U phase, V
V phase, W
W phase
Industrial Device Solution Business Unit, Panasonic Corporation
No. SX-DSV03335 - 35-
50/60 Hz
+ 10 %
50/60 Hz
- 15 %
50/60 Hz
50/60 Hz