Size F 200 V
Use terminal blocks.
Terminal block
No.
Symbol
(From above)
1
L1
2
L2
3
L3
4
L1C
5
L2C
6
P
7
RB
8
B
9
N
10
U
11
V
12
W
* Tighten the Earth screw with a torque of m, M5: 1.8 to 2.0 N · m..
* Tighten the terminal block screws with a torque of M5: 1.8 to 2.0 N · m.
* Tighten the fixing for the terminal block cover screws with a torque of M3: 0.19 to 0.21 N · m.
* The screws may be damaged if the tightening torque has exceeded the maximum value.
R2.0
Name
Main power input
3 phase 200 - 240 V
terminal
Control power input
Single-phase 200 - 240 V
terminal
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between RB
and B and connect an external regenerative resistor between P and B.
Regenerative resistor
In addition, parameter setting is required for the regenerative resistor.
connecting terminal
For details, refer to "Technical Reference - Functional Specification ".
Do not connect anything to the N terminal.
Connect each phase of the motor wiring.
Motor output terminal
U
Earth terminal for grounding
Earth
Description
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
:
:
:
U phase, V
V phase, W
W phase
Industrial Device Solution Business Unit, Panasonic Corporation
No. SX-DSV03335 - 37-