Size F 400 V
Use terminal blocks.
Terminal block
No.
Symbol
(From above)
-
1
-
2
3
L1
4
L2
5
L3
6
P
7
RB
8
B
9
N
10
U
11
V
12
W
Connector
Pin No.
Symbol
1
24V
XD
2
0V
* Tighten the Earth screw with a torque of M5: 1.8 to 2.0 N · m.
* Tighten the terminal block screw with a torque of M4: 1.8 to 2.0 N · m.
* Tighten the terminal screw cover fixing screw with torque of M3: 0.19 to 0.21 N · m.
* The screws may be damaged if the tightening torque has exceeded the maximum value.
R2.0
Name
Non-connection
Main power input
3-phase 380Y/220-480Y/277 V
terminal
TN (Ground the neutral point)
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between
RB and B and connect an external regenerative resistor between P and B.
Regenerative resistor
In addition, parameter setting is required for the regenerative resistor.
connecting terminal
For details, refer to "Technical Reference - Functional Specification ".
Do not connect anything to the N terminal.
Connect each phase of the motor winding.
Motor output terminal
U: U phase
Earth terminal for grounding
Earth
Name
Control power
DC 24 V
input terminal
Description
+ 10 %
- 15 %
V: V phase
W: W phase
Description
± 15 %
Industrial Device Solution Business Unit, Panasonic Corporation
No. SX-DSV03335 - 41-
50/60 Hz