Integrated Storage Controller Card; Removing Integrated Storage Controller Card - Dell EMC PowerEdge R740xd Installation And Service Manual

Hide thumbs Also See for PowerEdge R740xd:
Table of Contents

Advertisement

Next steps
1. If applicable,
install the expansion card riser
2. If applicable, install the
rear drive
3. Follow the procedure listed in

Integrated storage controller card

Removing integrated storage controller card

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the air
shroud.
4.
Remove the expansion card riser
Steps
1. Using Phillips #2 screwdriver, loosen the screws that secure the integrated storage controller cable to the system board.
2. Lift the integrated storage controller cable away from the integrated storage controller.
Figure 121. Removing integrated storage controller cable
3. Lift one end of the card and angle it to disengage the card from the integrated storage controller card holder on the system board.
4. Lift the card out of the system.
5. Hold the interposer board by its edges, and pull the board until the connector on the board disengages from the connector on the
system board.
170
Installing and removing system components
2.
cage.
After working inside your system
Safety
instructions.
Before working inside your
1.
on page 72.
system.

Advertisement

Table of Contents
loading

Table of Contents