Yamaha ERCX Series User Manual page 29

Single-axis robot controller
Hide thumbs Also See for ERCX Series:
Table of Contents

Advertisement

■ Return-to-origin command (ORG-S)
This command returns the robot to its origin position when the search method is selected as the
origin detection method. When the mark method is selected, this command checks the return-to-
origin status.
n
NOTE
Once return-to-origin is performed after the robot cable and absolute battery are connected, there is no need to
repeat it even when the controller is turned off. (As an exception, return-to-origin becomes incomplete if the
absolute backup function is disabled or a parameter relating to the origin is changed. Return-to-origin must be
reperformed in that case.)
c
CAUTION
When performing return-to-origin by the stroke-end detection method, do not interrupt return-to-origin
operation while the origin position is being detected (robot is making contact with its mechanical limit).
Otherwise, the operation will stop due to a controller overload alarm and the power will need to be turned off
and back on again.
c
CAUTION
If return-to-origin must be repeated by the stroke-end detection method, wait at least 5 seconds before repeating
it.
■ Servo recovery command (SERVO)
After emergency stop, releasing the emergency stop button and turning this input on (closing
the contact) turns the servo power on, so the robot is ready for restart.
(As with other dedicated command inputs, the servo recovery command should be a pulse
input, so it must be turned off (contact open) when the BUSY signal turns on.)
■ Reset command (RESET)
This command returns the program step to the first step of the lead program and turns off DO0 to
DO12 and the memory I/O. It also clears the point variable "P" to 0.
* When PRM33 ("Operation at return-to-origin complete" parameter) is set to 1 or 3, DO4 does
not turn off even if the reset command is executed. Likewise, when PRM46 ("Servo status
output" parameter) is set to 1, DO7 does not turn off even if the reset command is executed.
n
NOTE
The lead program is the program that has been selected as the execution program by the TPB or POPCOM. (See
"9-4 Switching the Execution Program".)
The lead program can also be selected by executing a communication command "@SWI". It may also be selected
when the program data is loaded into the ERCX controller from the memory card.
3-2 Input Signal Description
5
3-
3