No.
Symptom
Possible Cause
7
Robot starts
1)
Motor and/or
moving at high
resolver are
speed when the
miswired.
power is turned
on.
2)
Parameter error
* The ERCX
controller has
a safety
circuit to
detect wire
breakage, but
check the
points listed
on the right
anyway.
8
Robot speed is
1)
Parameter setting
abnormally fast
error
or slow.
2)
Speed setting was
changed.

13-3-2 Relating to the I/O

No.
Symptom
Possible Cause
1
Output signal
1)
Wiring to external
cannot be
devices is
controlled.
incorrect.
* In cases other
than cause 2,
the output
2)
Misprogramming
signal cannot
be controlled
even with the
3)
Output transistor
manual
is defective.
instruction of
TPB general-
purpose output.
2
Robot will not
1)
Return-to-origin
move even
has not yet been
with dedicated
completed.
command
2)
Program cannot
input.
be run.
3)
Signal pulse width
is too narrow.
4)
Time interval
before inputting a
dedicated command
after canceling
emergency stop is
too short.
5)
Interlock signal
remains off.
6)
Another dedicated
command input is
on.
13-3 Troubleshooting for Specific Symptom
Items to Check
• Check the motor wire and resolver
signal wire connections.
• Check whether the robot setting
displayed on the TPB matches the
robot actually used.
• Check the speed parameter (PRM30).
Items to Check
• Check the wiring.
• Check the operation with the manual
instruction of the TPB general-purpose
output. (Refer to "7-4 Manual Control
of General-Purpose Output".)
• Connect the TPB and check the
program.
• Measure the voltage at the PLC input
terminal.
ON: 0.5V or less
OFF: +IN COM (+24V)
• Connect the TPB and check the
operation.
• Connect the TPB and check the
operation.
• Check that the signal pulse width is
50ms or more.
• After canceling emergency stop, allow
at least 200ms before inputting a
dedicated command before inputting a
dedicated command.
• Check the signal by using the TPB DIO
monitor.
• Check the signal input (by using a PLC
monitor, etc.).
Action
• Correct the connections.
• Try initializing the parameters.
• If they do not match, initialize the
parameters.
• Correct the parameter.
Action
• Make the correct wiring by referring to
the connection diagram.
• Correct the program.
• Replace the ERCX controller if the
output transistor is defective.
• Reperform return-to-origin.
• Eliminate the cause of error by
referring to the error message.
• Increase the signal pulse width ("on"
duration).
• Increase the delay time.
• Turn on the interlock signal.
• Turn off the dedicated command input.