Transmit Labels in Code 39 Format

This feature enable/disables translation to Code 39 before transmitting label
data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is mod-
ified for the translation. The data is not converted to Code 39 or verified to be
valid for Code 39.
Options are:
IBM Standard Format:
Code 39 Format:
• USB-OEM: Code128, Code 93, and Codabar
• IBM-Port 5B: Code 128, Code 93, and Codabar
• IBM-Port 9B: Code 93 and Codabar
DEFAULT
Transmit Labels in Code 39 Format = Code 39 Format

Interface Options

This feature provides for an interface-specific control mechanism.
Ignore Scanner Configuration Host Commands
74
Send labels in standard IBM format.
Translate the following symbologies to Code 39:
Transmit Labels in Code 39 Format = IBM Standard Format
ENTER/EXIT PROGRAMMING MODE
Obey Scanner Configuration Host Commands
DEFAULT