USB-OEM Interface

Transmit Labels in Code 39 Format

This feature enable/disables translation to Code 39 before transmitting label data to a USB-
OEM host. Only the symbology identifier is modified for the translation. The data is not con-
verted to Code 39 or verified to be valid for Code 39.
Options are:
IBM Standard Format:
Mixed IBM Standard and Code 39 Format:
Translate the following symbologies to Code 39:
Code 39 Format:
• USB-OEM: Code128, Code 93, and Codabar
DEFAULT
$CIBC301(CR)
Transmit Labels in Code 39 Format =
Mixed IBM Standard and Code 39 format
Product Reference Guide
Send labels in standard IBM format.
Enter/Exit Programming Mode
$CIBC300(CR)
Transmit Labels in Code 39 Format =
IBM Standard Format
$CIBC302(CR)
Transmit Labels in Code 39 Format =
All Code 39 Format