Technical Specifications
Table 51
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
A valid programming label has
ming Mode
been scanned.
Entry
Label Program-
ming Mode
A label has been rejected.
Rejection of
Label
In cases where multiple labels
Label Program-
must be scanned to program
ming Mode
one feature, this indication
Acceptance of
acknowledges each portion as
Partial Label
it is successfully scanned.
Configuration option(s) have
Label Program-
been successfully pro-
ming Mode
grammed via labels and the
Acceptance of
reader has exited Program-
Programming
ming Mode.
Label Program-
ming Mode Can-
Cancel label has been scanned.
cel Item Entry

Error Codes

Upon startup, if the reader sounds a long tone, this means the reader has not
passed its automatic Selftest and has entered FRU (Field Replaceable Unit) iso-
lation mode. If the reader is reset, the sequence will be repeated. The following
table describes the LED flashes/beep codes associated with an error found.
NUMBER OF
LED FLASHES/
BEEPS
1
2
4
6
14
320
. Programming Mode Indications
ERROR
Configuration
Interface PCB
Reader Module
Digital PCB
CPLD/Code Mismatch
LED blinks continuously
N/A
N/A
N/A
N/A
CORRECTIVE ACTION
Contact Helpdesk for assis-
tance
Gryphon™ I GD4132/GM4102/GBT4102
Reader sounds four low fre-
quency beeps.
Reader sounds three times at
lowest frequency & current
volume.
Reader sounds one short beep
at highest frequency & current
volume.
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by
reset beeps.
Reader sounds two times at
low frequency and current vol-
ume.