ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character
from the host following label transmission. The selectable timeout range is 200
milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0
disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the
3. Go to
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
this feature.
Table 31. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
page 53
and scan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
that represent the duration which was determined in the steps above. You
will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
Mode.
EXAMPLES
200ms
01
'0' and '1'
Table 31
for some examples of how to set
1,000ms (1 sec.) 5200ms (5.2 sec.)
05
26
'0' and '5'
'2' and '6'
RS-232 Parameters
Appendix D,
Keypad,
15,000ms (15 sec.)
75
'7' and '5'
287