11.3 Input data, PMX −> control (PLC)

11.3.1 Device data (cyclic)

Function

System status

Parameter set
GUI status
Limit value
switch status
Limit value reset
acknowledge-
ment
Time stamp
Digital outputs
11.3.2 System status
Bit
0
Error in factory settings
1
Device is Sync Master
2
3
4
5
6
catman interface buffer overrun
see below
Currently active parameter
set
- not in use -
Bit x = 1: limit value switch
x is set
Acknowledgement of the
"Limit value switch reset
request";
Acknowledgment same as
request means: Reset has
been performed
PMX time stamp, counts
with 153.6 kHz
Current status
Function
Sync error
Sync error
Heartbeat
Excitation overload
PROFINET
EtherCAT
slot.subslot
index
6000.1
0.2
bytes 0..3
6000.2
0.2
bytes 4..7
6000.3
0.2
bytes 8..15
6000.4
0.2
bytes 16..19
6000.5
0.2
bytes 20..21
6000.6
0.2
bytes 22..29
6000.7
0.2
bytes 30..33
Also set in the single-user device
No connection or disrupted
connection
Synchronization not possible
Bit switches with approx. 1 Hz
Excess current caused by external
consumers (transducer excitation)
Data transmission error, loss of data
Communication
Data
type
uint32
int32
uint64
uint32
uint16
uint64
uint32
A3257−2.0 en/de/fr