Measured Values (Cyclic) - HBM PMX Operating Manual

Measuring amplifier system
Hide thumbs Also See for PMX:
Table of Contents

Advertisement

Communication

11.3.3 Measured values (cyclic)

Function
Flags
Flags status
Flags control
word
acknowledge-
ment
Digital inputs
Digital inputs
status
Digital inputs
control word
acknowledge-
ment
Measured
value slot x.y
Measured
value
status
Measured
value control
word
acknowledge-
ment
- - -
Calculated
channel in slot
9.z
Status
Control word
acknowledge-
ment
_
A3257−2.0 en/de/fr
Status flags from
calculated channels; not
currently assigned
always 0
'Flags control word'
return 7001.1
Level of the digital
inputs
always 0
'Digital inputs
control word' return
see 'Measured value
status' table
Control word return
70xy.2
Number dependent on
the connected
measurement cards
see 'Measured value
status' table
Control word return
Number dependent on
the number of calculated
channels set on the
fieldbus
PROFINET
EtherCAT
slot.subsl
index
ot
6001.1
0.3
bytes 0..3
6001.2
0.3
byte 4
6001.3
0.3
byte 5
6002.1
0.4
bytes 0..3
6002.2
0.4
byte 4
6002.3
0.4
byte 5
60xy.1
x.y
bytes 0..3
60xy.2
x.y
byte 4
60xy.3
x.y
byte 5
60xy.1
9.z
bytes 0..3
60xy.2
9.z
byte 4
60xy.3
9.
byte 5
103
Data
type
uint32
uint8
uint8
uint32
uint8
uint8
float32
uint8
uint8
float32
uint8
uint8

Advertisement

Table of Contents
loading

Table of Contents