Download Print this page

Technical Data - HBM C16i series Installation Instructions Manual

Digital load cell
Hide thumbs Also See for C16i series:

Advertisement

Available languages

Available languages

Wägezelle
Load cell
4

Technical data

Type
Max. capactity (E
)
max
Accuracy class accord. to OIML R60
Max. numbers of load cell
verification intervals (n
LC
Min. load cell verification interval
(v
)
min
Min. scale verification interval
(e
) according to EN 45 501
min
[... LC = max. Number of load cells]
Sensitivity (C
)
n
Sensitivity tolerance
Temperature effect
1)
on sensitivity (TK
)
C
Temperature effect
on zero signal (TK
)
0
1)
Hysteresis error (d
)
hy
1)
Non-Linearity (d
)
lin
Creep (d
), 30 min.
cr
Reference excitation voltage (U
Nominal range of
excitation voltage (B
)
U
Current consumption
Resolution
Measuring rate
Filter mode 0
Filter mode 1
Asynchrone Interface
Baudrate
Number of bus adresses
Nominal temperature range (B
Service temperature range (B
Storage temperature range (B
Limit load (E
)
L
Breaking load (E
)
d
Permissible dynamic load (F
(vibration amplitude according to
DIN 50100)
Deflection at E
(s
max
nom
Weight (G) with cable, approx.
Protection class according to
EN60529 (IEC529)
Material:
Meas. body + housing
Cable fitting
Sealing
Cable-sheath
1)
The data for Non--Linearity (d
sum of these data meets the requirements for p
2)
Please refer to the table for the power supply on page 16!
MA.C16i.0def -- 284.00--1053.4 -- Version a -- 05.04.2001
français (page 18 ... 25) = en préparation
Capteur de pesage
20t
)
%
of E
max
kg
--
digit
%
% of
C /
C
/
n
10K
% f
% of
C
C
n
n
)
ref
V (DC)
mA
Bit
/ sec
Hz
Hz
Baud
)
T
)
°C [°F]
[ ]
tu
)
tl
%
of
f
)
srel
E
max
), approx.
mm
0.65
kg
2.2
), Hysteresis error (d
lin
= 0.8 according to OIML R60.
LC
C16i...
C16i D1
30t
40t
60t
D1 (0.0330%)
1000
0.0200
--
--
1 000 000
≤ ± 0.0100
1)
≤ ± 0.0250
≤ ± 0.0285
1)
≤ ± 0.0330
1)
≤ ± 0.0300
≤ ± 0.0330
20 (at 1Hz)
100 | 50 | 25 | 12 | 6 | 3 | 2 | 1
8 ... 0.05 (Low pass filter)
8 ... 3 (Low pass filter)
RS-485 / 4-wire (Cable lenght up to 500m)
1200 ... 38400
--10 ... +40 [14...104]
--20 ... +70 [-4...158]
--50 ... +85 [-58...185]
0.75
0.85
1.22
2.4
3.0
3.8
IP68 (test conditions 100h at 1m water column)
IP69K (water at high pressure, steam jet cleaning)
stainless steel
stainless steel
thermoplastical elastomer
) and Temperature effect on sensitivity (TK
hy
C16i C3
20t
30t
C3 (0.0180%)
3000
0.0100
5
[6 LC]
10
[6 LC]
--
[10 LC]
10
[10 LC]
[10 LC]
≤ ± 0.0080
≤ ± 0.0140
≤ ± 0.0170
≤ ± 0.0180
≤ ± 0.0167
12
2)
7 ... 15
2)
50
max. 32
150
> 350
70
0.65
0.75
0.85
2.2
2.4
neoprene
) are typical values. The
C
17
40t
60t
0.0083
10
10
[4 LC]
20
20
[10 LC]
1)
≤ ±
0.0116
1)
1)
1.22
3.0
3.8

Advertisement