Upload Configuration; Download Configuration; Ez Cal Ii Control Buttons - Thermo Scientific LevelPRO User Manual

Advertisement

Upload
Configuration
Download
Configuration
EZ Cal II Control
Buttons
Thermo Scientific
Uploading a configuration file provides the user with a way to save all configured
parameters from the detector to the computer. In the event of a cold start, the file can
then be downloaded back to the detector to reinstall the set parameters.
1. To save a file configuration from the detector to the computer, click the Upload
CFG from Gauge button.
2. Enter a name for the configuration file and click Save.
3. To abort the upload, click the Abort button.
1. To download a previously-saved configuration file back to the detector, click the
Browse File button.
2. Select the .cfg file to be downloaded and click Open. The name of the file will
appear in the File Name field.
3. To save the file as a shortcut for quick access in the future, click the Save to List
button. Doing this will add the file to the Save Old Config Files list box. Once a
file has been saved to this list, the user can set up the file for download to the
detector by simply double-clicking the file name and clicking the Download File
to Gauge button.
To delete a file from the list, highlight the file and click the Delete button.
This will delete the file from the list but not from the computer.
4. In order to save the configuration to the detector permanently, click the Write to
Flash Again button. This will ensure that the specified parameters are loaded each
time the system boots.
Sometimes it may be preferable to load parameters into the detector for only a
short time, such as while running a specific test. In this instance, once the
parameters have been downloaded to the detector, the process is complete.
Once the detector is shut down, the configuration parameters will revert to the
last configuration written to flash.
The following buttons are seen consistently throughout the EZ Cal II software:
Abort – Stops the current process.
Auto Refresh – Continuously refreshes the screen with data from the detector.
Back – Moves the user to the previous screen.
Cancel – Closes the current screen.
Home – Returns the user to the Detector and Application Type Selection screen,
Figure
3-3.
Next – Moves the user to the next available screen.
Refresh – Updates the screen with the latest information from the detector.
Submit – Saves any information entered on the current screen to the detector.
If a screen has multiple Submit buttons, each button will apply to a separate,
portioned-off area of the screen.
Product Overview
Features
LevelPRO User Manual
3-3