Sign In
Upload
Manuals
Brands
Thermo Scientific Manuals
Measuring Instruments
410iQ
Thermo Scientific 410iQ Manuals
Manuals and User Guides for Thermo Scientific 410iQ. We have
1
Thermo Scientific 410iQ manual available for free PDF download: Instruction Manual
Thermo Scientific 410iQ Instruction Manual (306 pages)
Carbon Dioxide Analyzer
Brand:
Thermo Scientific
| Category:
Measuring Instruments
| Size: 19.9 MB
Table of Contents
Table of Contents
3
Chapter 1 Introduction
9
Iq Series Instrument Platform
9
Figure 1-1. 410Iq Front
10
410Iq Principle of Operation
11
Figure 1-2. 410Iq Flow Schematic
12
Figure 1-3. 410Iq Flow Schematic with Zero Span
12
Specifications
13
Table 1-1. 410Iq Specifications
13
Table 1-2. 410Iq Optional Internal Oxygen Sensor Specifications
14
Dimensions
15
Figure 1-4. Bench Mount Assembly (Dimensions in Inches [MM])
15
Figure 1-5. Rack Mount Assembly (Dimensions in Inches [MM])
16
Figure 1-6. Rack Mount Requirements
17
Chapter 2 Installation and Setup
19
Unpacking and Inspection
19
Cover Removing and Replacing
20
Figure 2-1. Removing the Cover
20
Mounting Options
21
Bench Mount
21
Figure 2-2. Installing Feet
21
Rack Mount
22
Figure 2-3. Removing the Front Panel
22
Figure 2-4. Installing Ears and Handles
23
Setup Procedure
24
Figure 2-5. 410Iq Rear Panel
25
Figure 2-6. Atmospheric Dump Bypass Plumbing
25
Startup
26
Figure 2-7. Front Panel and Touchscreen Display
26
Chapter 3 Operation
27
Instrument Display
27
Main Menus and Keypads
32
Numeric Keypad
33
Alphanumeric Keypad
34
Calibration
36
Calibrate Background
38
Calibrate Span Coefficient
39
Zero/Span Schedule
41
Calibrate O 2 Span Coefficient
43
Advanced Calibration
44
Manual Calibration
46
Multipoint Calibration
51
Manual O Calibration
54
2-Point O Calibration
56
Calibration History
58
Data
59
View Data Log (Last Hour)
60
View Data Log (Last 24 Hours)
61
View Data Log (User Defined Time)
62
Advanced Data
64
Data Logging Setup
65
Select Data Logging Variables
66
Streaming Data Setup
67
Select Streaming Variables
68
Settings
69
Health Check
70
Status and Alarms
71
Concentration
72
NDIR Bench
74
Flow and Pressure
79
Peripherals Support
81
Valve and Pump Resets
83
Serial Numbers
88
Predictive Diagnostics
89
Maintenance
90
Preventive Maintenance
91
Change Part
93
Maintenance History
94
File Sharing and Support
95
Iq360
96
Measurement Settings
99
Averaging Time
101
Range Mode Selection
103
Range Setting
105
Gas Mode
106
Gas Units
107
Advanced Measurement Settings
108
Communications
116
Wired TCP/DHCP
118
Analog I/O
121
Digital I/O
122
Email Server (SMTP)
123
Bayern Hessen Settings
124
Ethernet Protocol Selection
125
Instrument Settings
126
Display Setup
127
Alarm Setpoints
128
Clock
131
Time Zone
135
Configuration
138
Security Access Levels
139
Change Security to View Only Access
141
Change Full Access Security Password
142
Change Instrument Password
144
Reset Instrument Password
146
USB Drive
147
Firmware Update Via USB Drive
148
Download Data to USB Drive
152
Change USB Password
155
Reset USB Password
157
User Contact Information
158
Update Bootloader
159
Chapter 4 Calibration
161
Equipment Required
161
CO Concentration Standard
161
Zero Air Generator
161
External Flow Meter(S) and Controller(S)
162
Pre-Calibration
162
Calibration
163
Connect the Instrument
163
Figure 4-1. Calibration Flow Schematic
163
Detector Gain
164
Initial S/R
165
Multipoint Calibration
166
High and Low Multipoint Calibration
168
Calibration Frequency
168
Calibrate Background
169
Calibrate Span Coefficient
170
Periodic Zero and Span Checks
172
Manual Calibration
173
Adjust Background
173
Adjust Span Coefficient
174
Zero/Span Schedule
175
Next Time
175
Period
175
Zero/Span/Purge Duration Minutes
175
Schedule Averaging Time
176
Background Calibration and Span Calibration
176
Zero Calibration and Span Calibration
176
Zero/Span Ratio
176
Chapter 5 Maintenance
177
Safety Precautions
177
Fan Filter Inspection and Cleaning
177
Pump Rebuilding
178
Figure 5-1. Single Stage Pump
178
Figure 5-2. Pump Rebuilding
180
Leak Test
181
IR Source Replacement
182
Chapter 6 Troubleshooting
183
Safety Precautions
183
Troubleshooting Guide
183
Table 6-1. 410Iq Troubleshooting Guide
183
Chapter 7 Servicing
189
Safety Precautions
189
Figure 7-1. Properly Grounded Antistatic Wrist Strap
190
Firmware Updates
191
Replacement Parts List
191
Figure 7-2. 410Iq Component Layout Top View (Standard)
192
Figure 7-3. 410Iq Component Layout Side View (Standard)
192
Figure 7-4. 410Iq Component Layout Top View (High Level)
193
Figure 7-5. 410Iq Component Layout Side View (High Level)
193
Fuse Replacement
194
Figure 7-6. Replacing the Fuses
194
Filter Replacement
195
Figure 7-7. Start with Top Right Corner of Fan Cover
195
Figure 7-8. Removing the Fan Cover
195
Fan Replacement
196
Figure 7-9. Unplugging the Fan Cable
196
Figure 7-10. Replacing the Fan
197
Measurement Side Removal
198
Figure 7-11. Unplugging the Fan Cable
198
Figure 7-12. Unplugging the DMC Cable
199
Figure 7-13. Unfasten Hardware Front for Measurement Side Removal
200
Figure 7-14. Unfasten Hardware Rear for Measurement Side Removal
201
LCD Module Replacement
202
Figure 7-15. Replacing the LCD Module
202
Figure 7-16. Remove Electrical Cables from LCD
203
I/O Replacement
204
Figure 7-17. I/O Replacement, Arm
204
Figure 7-18. I/O Replacement, Remove Board
204
Figure 7-19. I/O Replacement, Install
205
Figure 7-20. I/O Replacement, Close Arm Alignment
205
Peripherals Support Board and System Controller Board Replacement
206
Figure 7-21. Replacing the Peripherals Support or System Controller Board
206
DMC Pressure and Flow Board
207
Figure 7-22. Flow Pressure Board, Disconnect DMC Cable
207
Figure 7-23. Flow Pressure Board, Screws
208
Pump Replacement
209
Figure 7-24. Remove Pump, Disconnect and Unfasten
210
Figure 7-25. Pump Removal, Keyway
211
Figure 7-26. Pump Replacing, Unfasten Screws
211
Capillary Cleaning And/Or Replacement
212
Figure 7-27. Remove Capillary, Disconnect and Unfasten
212
Figure 7-28. Capillary Plate, Keyway
213
Figure 7-29. Capillary and O-Ring Replace
213
Capillary O-Ring Replacement
214
Power Supply Replacement
214
Figure 7-30. Removing Power Supply
215
Figure 7-31. Replacing Power Supply
215
Step POL Board Replacement
216
Figure 7-32. Unplug and Unfasten Step POL Board
216
Figure 7-33. Clear Partition Keyway Step POL Board
217
Figure 7-34. Step POL Board 1 Switch Settings
218
Figure 7-35. Optional Step POL Board 2 Switch Settings
218
DMC Optical Bench
219
Figure 7-36. DMC Layout (Standard)
219
Figure 7-37. DMC Layout (High Level)
220
Optical Bench Removal
221
Figure 7-38. DMC Removal from Instrument (Standard)
221
Figure 7-39. DMC Removal from Instrument (High Level)
222
Optical Switch Replacement
223
Figure 7-40. Motor and Chopper Removal Pt 1 (Standard)
223
Figure 7-41. Motor and Filter Removal Pt 1 (High Level)
224
Figure 7-42. Motor and Filter Removal (Pt 2) (Standard)
225
Figure 7-43. Motor and Filter Removal (Pt 2) (High Level))
225
Figure 7-44. Optical Switch Replacement (Pt 3) (Standard)
226
Figure 7-45. Optical Switch Replacement (Pt 3) (High Level)
227
Purge Wheel Housing Removal
228
Figure 7-46. Purge Housing Removal from Motor Assembly (Pt 4) (Standard)
228
Figure 7-47. Purge Housing Removal from Motor Assembly (Pt 4) (High Level)
229
Filter Wheel Replacement
230
Figure 7-48. Filter Wheel
231
Motor Replacement
232
Figure 7-49. Motor Removal from Motor Mount Pt 1
232
Figure 7-50. Motor Removal
233
Motor and Filter Wheel Alignment
234
Figure 7-51. Motor Installation Shaft Alignment
235
Optical Bench Heater Removal
236
Figure 7-52. Need Description
236
Figure 7-53. Heater Removal (Standard)
237
Figure 7-54. Heater Removal Part 2 (Standard)
237
Figure 7-55. Heater Removal (High Level)
238
Pre-Amp/Detector Assembly Removal
239
Figure 7-56. Preamp Detector Cover Removal Pt 1 (Standard)
239
Figure 7-57. Preamp Detector Cover Removal Pt 1 (High Level)
240
Figure 7-58. Preamp/Detector Removal (Standard)
240
Figure 7-59. Preamp/Detector Removal (High Level)
241
IR Source Replacement
242
Figure 7-60. IR Source Cable Disconnect (Standard)
242
Figure 7-61. IR Source Cable Disconnect (High Level)
243
Figure 7-62. IR Source Assembly Removal (Standard)
244
Figure 7-63. IR Source Assembly Removal (High Level)
244
Optional Manifold Replacement
245
Figure 7-65. Replacing the Manifold Pt 2
246
Figure 7-66. Replacing the Manifold Pt 3
246
Optional DMC Oxygen Sensor
247
Oxygen Sensor Removal
247
Oxygen Sensor Board Replacement
250
Figure 7-71. Replacing the Oxygen Sensor DMC Board
250
Oxygen Sensor Capillary Replacement
252
Figure 7-73. Replacing the Oxygen Sensor Capillary
252
Oxygen Sensor Replacement
254
Figure 7-75. Replacing the Oxygen Sensor
254
Chapter 8 System Description
255
Optical Bench DMC
255
Optical Bench Hardware
256
Filter Wheel Motor
256
Filter Wheel Purge
256
Figure 8-1. 410Iq Flow Schematic with Filter Wheel Purge (Standard)
257
Figure 8-2. 410Iq Flow Schematic with Filter Wheel Purge (High Level)
257
Detector Preamp
258
Infrared Source
258
Optical Bench DMC Board
258
Common Electronics
258
Figure 8-3. Common System Interconnect Diagram
259
Figure 8-4. 410Iq System Interconnect Diagram
260
Power Supply
261
Front Panel
261
System Controller Board
261
Backplane Board
261
Peripherals Support System
262
Step POL Board
262
Sample Pump
262
Solenoid Valve Panel (Optional)
262
Flow/Pressure DMC
262
Firmware
262
Oxygen Sensor (Optional)
263
Chapter 9 Optional Equipment
265
Connecting External Devices
265
Figure 9-1. I/O Expansion Replacement Boards
265
Communication Board
266
RS-232/RS-485 Port
266
RS-485 External Accessory Port
266
Figure 9-2. RS-232/RS-485 Port
266
Table 9-1. RS-232/RS-485 Port Terminal Assignment
266
Figure 9-3. RS-485 External Accessory Port
267
Table 9-2. RS-485 External Accessory Port Terminal Assignment
267
Analog I/O Board
268
Analog Voltage Inputs
268
Figure 9-4. Analog Voltage Inputs
268
Table 9-3. Analog Voltage Inputs Assignment
268
Analog Voltage Outputs
269
Figure 9-5. Analog Voltage and Current
269
Analog Output Calibration
270
Table 9-4. Analog Voltage and Current Assignment
270
Digital I/O Board
275
Digital Inputs
275
Figure 9-6. Digital Inputs
275
Table 9-5. Digital Inputs Terminal Assignment
276
Digital Relay Switches
277
Figure 9-7. Digital Relay Switches
277
Table 9-6. Digital Relay Switch Assignment
278
Valve Driver Outputs
279
Figure 9-8. Valve Driver Outputs
279
Table 9-7. Valve Driver Outputs Assignment
280
Internal Zero/Span Assembly
281
Figure 9-9. 410Iq Flow Schematic with Zero Span (Standard)
281
Figure 9-10. 410Iq Flow Schematic with Zero/Span (High Level)
281
Internal Oxygen (O ) Sensor
282
Figure 9-11. 410Iq Flow Schematic with Internal O
282
Figure 9-12. 410Iq Flow Schematic with Internal O
282
PTFE Particulate Filter
283
Appendix A Safety, Warranty, and WEEE
285
Safety
285
Safety and Equipment Damage Alerts
285
Warranty
286
WEEE Compliance
288
WEEE Symbol
288
Advertisement
Advertisement
Related Products
Thermo Scientific 410i
Thermo Scientific 49i
Thermo Scientific 48iQTL
Thermo Scientific 49iQ
Thermo Scientific 42iQ
Thermo Scientific Nicolet 4700
Thermo Scientific 42iQD
Thermo Scientific 43iQ
Thermo Scientific 450iQ
Thermo Scientific 4652140
Thermo Scientific Categories
Laboratory Equipment
Measuring Instruments
Accessories
Refrigerator
Freezer
More Thermo Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL