1.6 Symbols Warnings and cautions WARNING! Risk of personal injury or loss of life. CAUTION! The material may be damaged or the operation of the product affected. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
2.2 Operational Safety WARNING! Any children or minors using the product must be supervised and accompanied by a responsible adult. Boon Edam does not accept any liability if this rule is not enforced. WARNING! This product should not be considered as a playground.
The height of the glass door wings of the standard Speedlane 900 is 35 7/16 or 900 mm; the height of the high Speedlane 900 is 47 ¼ or 1200, 55 1/8 or 1400, 63 or 1600, 70 7/8 inch or 1800 mm.
For security reasons the blocking of the door wing is detected. 3.3 Spring unit on the wide and wide high versions A pre-loaded spring unit has been fitted to the wide and wide high versions of the Speedlane 900 to compensate for the weight of the glass panel.
The emphasis is on maximising safety and not on access security. The safety sensors are placed (at 7 inch or 180 mm and 23 inch or 580 mm from finished floor level) to ensure optimal safety. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
4 Operating concept 4.1 Operating functions The Speedlane 900 consists of two opposing units. The barrier is formed by two sliding doors. In a single Speedlane 900, each unit is equipped with one sliding door. In a set-up with multiple adjacent Speedlanes, each unit (except for the outside ones) is equipped with two sliding doors.
When a person is authorized by the access control system, the access control system gives a pulse to the Speedlane 900 control system. If the person passes the door panels a booking pulse can be given to the access control system.
The first person has to leave the Speedlane 900 at the side the other person is approaching to allow the second person to pass. When the unauthorized person does not step out, this person can pass the door wings using the authorization of the second person.
The medium security level is like the low security level; only the safety zone area that is used to detect unauthorized persons is narrower. This results in a higher level of tailgating prevention. When an authorized person steps into the Speedlane 900 and steps out, the authorization is void. 4.2.6 High security mode...
When the door wings close, while a person is standing in the safety zone, the door wings will open again with a slow speed. When the person has left the Speedlane 900 the door wings will close. Optical safety When the high security level is selected, and a person is in the safety zone, the door wings will close with a slow speed.
When the fire alarm is reset, the door wings will slowly turn to their closed position. The Speedlane 900 is then ready for normal operation. In case of a fire alarm all other safety features will be disabled. The fire alarm position always takes precedence over the locked position.
When an authorized person enters the Speedlane 900 the display of the entering side will ) be green ( . If the person is in the Speedlane 900 the display will be directly red () and the next person can be authorized. If there are more authorizations the display will become ...
4.4.2 Other alarms Malfunction alarm When the Speedlane 900 fails to initialise an alarm is generated. The alarm is also generated when the Speedlane 900 is mechanically blocked during operation. Malfunction alarm Anti-masking detection The Speedlane 900 has an anti-masking detection. Masking is the condition when one of the sensors is triggered (covered) continuously for more than 10 seconds.
Intruder alarm (entry/exit) When an unauthorized person enters the Speedlane 900 and activates one of the sensors, the acoustic alarm is generated. The alarm can be switched off or changed to “partial” mode. Partial mode means that the alarm will only be triggered when the intruder is standing in the safety zone of the Speedlane 900.
Before you start the installation, check your product on possible options. CAUTION! Check that all safety devices and systems are fully operational after installation of the door or after maintenance has been carried out. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
5.1.3 Anchoring Methods There are many anchoring methods. Typically, Speedlanes are anchored to concrete slabs. Boon Edam recommends using 3/8” masonry anchors or 10mm wired rods and chemical anchors. Sample Masonry Anchors 5.1.4 Connections Please use the following torque values for bolt connections, unless stated differently in the installation manual.
1 x Conduit to the Fire Alarm system. 1 x Conduit for Mains Power supply. Secure Side (Exit) 9 7/16” (240mm) Non-Secure Side 5 1/2” (Entry) (140mm) Typical Conduit Layout Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Alarm, Remote Control Panels and any other interface equipment that may integrate with the Speedlane units. Secure Side (Exit) 9 7/16” (240mm) 5 1/2” Non-Secure Side (140mm) (Entry) Typical Multiple Lane Conduit Layout Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
5.3 Anchoring 5.3.1 Anchoring points The anchoring points for a narrow or wide Speedlane 900 are the same. The Speedlane can be directly installed and anchored on the finished floor or with the use of an installation kit. 1 3/16” (30mm) 15 3/4”...
For all high units the top plate comes in two sections. Insert an Allen key wrench and loosen the Allen bolt Lift the end up. 2 Pull the top plate. Lift the top plate out. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Make sure to remove the earth connection wire. Lift the panel up. Turn panel out at the inside. Move the panel out. Be sure to disconnect the Earth (PE) cable. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
When removing the middle section please make sure to disconnect the sensor wiring as well as the earth connection wire. Screw location Screw location Take all four (4) screws and plastic spacers out Remove middle section to gain access to the center. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
5.5 Anchoring to the floor The Speedlane 900 can be anchored directly to the floor. Use the dimensions as shown in the Anchoring points drawing. Drill the holes and anchore the Speedlane to the floor using 3/8” masonry anchors or 10mm wired rods and chemical anchors.
Page 32
If this is correct, bolt the frame to the mounting plates. If not correct, use shim plates to level the Speedlane Complete installation of the frame Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
5.6 Doorwing glass installation The doorwings of all high Speedlane 900 models will come in a separate box inside the crate. The doorwings of the 35 7/16” [900 mm] high Speedlane will be pre-installed in our factory. Loosen the three bolts of the clamping strip.
- Cut out in glass is on the correct side. (Intermediate units have them on both sides. Position the glass over the cut-out and lower it in. Tighten the clamping screws again. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Page 35
5.6.2 Options For the long Speedlane additional tubes need to be installed as shown below. Please see project specific drawings for the mounting locations and wiring. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
The master – slave connection cable runs from the master unit to the slave unit. It is connected to the terminal strip in the slave, wire number 1 to terminal 1, wire 2 to 2, etc. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Page 39
Door open alarm common Traffic green non sec Card reader non sec IN Card reader non sec GND Traffic sec Traffic red non sec Card reader non sec reply Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
7.2.1 Transmitter The transmitter is located in the Slave unit. With a multi-lane installation it can happen that the emitters of one Speedlane 900 have influence on the receivers of the adjacent Speedlane 900. This can be adjusted with the potentiometer on the emitter. With the potentiometer on the Multibeam emitter, you can reduce/increase the power to the Multibeam emitters.
Switch 3 = OFF Switch 4 = OFF If a second Multibeam is mounted in a long or high Speedlane 900 the 4 DIP-switches of the second MBR must be set in the following configuration: Switch 1 = ON ...
Non Secured Secured 7.3.2 Standard High model (Master) Multibeam 1 Multibeam 2 Non Secured Secured 7.3.3 Extended High model (Master) Multibeam 1 Multibeam 2 Non Secured Secured Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
- Sensor 6 or 14 triggers the closing of the wings. In medium or high security mode - Sensor 7 or 8, sensor 15 or 16 triggers the closing of the wings. Non Secured Secured Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
In one direction it is done by sensors 7 & 1 and the other direction by sensors 15 & 1. Sequence is: Sensor 7 Sensor 1 Sensor 7 Off. Sensor 1 Off. Return signal Sensor 7 is in the other direction sensor 15. Non Secured Secured Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Generally, the Speedlane 900 will be pre-configured by Boon Edam and is ready for use after proper installation. Any user programmable settings have been set to their default values and need no further adjustment.
The selection menu is shown on the LCD screen and operated with the four push buttons directly under the display. When adjusting the selection menu it is recommendable to switch the Speedlane 900 in the ‘Open’ position. The table below gives the menu items with the default settings and the setting range.
Selection Menu jumps back to the second level. The same happens in the second level, but with a response time of five seconds. When the Selection Menu jumps from the second level to the first level, the Speedlane 900 will reinitialise and adjustments in parameters will be stored in the memory of the microprocessor.
SL900HLW extended and wide Speedlane 900 with high glass wings When one of the high Speedlane 900 models is selected, a further selection has to be made on the number of additional safety sensor pairs (1 to 5). In case of an extended Speedlane 900 model, a further selection has to be made on the number of additional sensor pairs (1 to 4).
Sensor 2 and 10 are not active and can be used as spares. 8.3.6 Entry time The entry time to pass the Speedlane 900 is adjustable from 1 to 20 seconds. The entry time is the time between an authorization and passing the Speedlane 900. If this time is finished the Speedlane 900 closes.
In the “Off” position all functionality still works only the buzzer will not beep anymore. 8.3.16 Last action In this menu you can select the last action to be performed by the Speedlane 900 in case of low battery power (long period of mains absence): open or close.
It is possible to restore all default settings in the Selection Menu with one action. The default values are set by pressing ‘Enter’ in the menu ‘Default’ in level two. After ten seconds the Speedlane 900 will reinitialise and all the adjustments are restored to the factory settings. Page:...
NOTE!: Normally no changes will have to be made to the Frequency Inverter parameter settings. Only in case the factory (Boon Edam) settings are incorrect or have been lost it will be necessary to restore the factory (Boon Edam) settings.
"setting dial". The example below shows the operational steps for changing the Maximum frequency parameter (Pr. 1) setting from 120.0 to 50.00 Hz. Parameter setting example Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
The procedure below shows the operational steps for returning the parameter settings of one parameter or all parameters to the factory default of the Frequency Inverter manufacturer. NOTE!: After this factory reset a number of parameters must be set to the Boon Edam (BEBV) setting. See section 10.1.
Speedlane 900 is free from any malfunctions. NOTE!: Only a limited number of parameters may be changed. It is important to know that not all parameters are given here. Each Speedlane 900 type has a different parameter set to give the best operation.
100-150 Parameter default and setting range – Standard, High and Long Speedlane 900 Wide Boon Edam default parameters and range. NOTE!: The parameter settings for the Speedlane 900 Wide are for lanes which have a spring unit installed. Function 900-W&LW 900-W&LW...
11.1 Uploading the software In some cases the Speedlane 900 software will need to be updated. The computer program Flash Magic is used to upload the Speedlane 900 software into the microprocessor. Connect your computer to the communication port on the MCB.
Select the device by clicking on the arrow on the right side of the Device field. Select XA-G49. Set the oscillator frequency to 11 MHz by typing 11 in the Oscillator Freq (MHz) field. The communication settings are now ready. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
For each new upload cycle, only Start needs to be pressed. To leave the programming mode and to enter the normal operating mode, press the right (Reset) button and release it. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
After installation of the side covers make sure to connect the Earth cable 1. Move the panel in over the pins. 2. Turn panel in at the inside. 3. Push the panel down. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
With a two piece top plate. Place the center part first and slowly lower the top plate into place. Insert an Allen key wrench and tighten the Allen bolt Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Check the floor mountings and fasten where needed. Check the motor mountings and fasten where needed. Check the whole installation for correct alignment with floor (surroundings). Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
When the fuse appears to be all right, the MCB might need to be replaced. Try powering down the whole Speedlane 900 by shutting down the UPS and waiting for approx. 30 seconds before powering it back up. ...
Fire alarm Check fire alarm signal Open button Button stuck / broken Low battery Check UPS Power failure Check Speedlane on power supply Speedlane 900 Error states Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Operation could not be resumed properly within the pre-set number of retries. CPU error Arithmetic operation of the built-in CPU does not end within the predetermined time. Frequency Inverter error codes Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
The UPS performs a self-test automatically when turned on, and every two weeks thereafter (by default). One of the alternative settings is to perform a self test at power up. Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Switch A and B signals of both angle encoders. aren’t connected acoustic alarm, traffic Check the encoder status in the menu. signals and intruder alarm properly work properly Other errors Page: OIM - Manual Version: 2014/11 Speedlane 900 Edition: SL900 -OIM - USA...
Omron inverter. Software updates Please note that when updating the software in the Speedlane 900 the old version is completely overwritten by the new version. This can only be done in case the current software does not contain custom functionality.