8.2 Adjustments selection menu

The Speedlane 900 has a build in selection menu.
The selection menu is shown on the LCD screen and operated with the four push buttons directly
under the display.
When adjusting the selection menu it is recommendable to switch the Speedlane 900 in the 'Open'
position.
The table below gives the menu items with the default settings and the setting range.
Menu Item
Signalling mode
Security mode
Model selection
Door closing speed
Sensor usage
Entry time [seconds]
Hold time [seconds]
Reply time [deci seconds]
Gate open
Intruder alarm
Error state
Encoder data
Multibeam
Maximum authorizations
Buzzer
Last action
Card reader mode
Free In / Out mode
Frequency inverter model
Default settings
Left and Right:
- Can be used to scroll through options within the same menu level.
Enter:
- Can be used to go to the next menu level, in the lowest menu level.
- Is used to store the chosen value or option.
Escape
- Can be used to leave the menu level, in the highest menu level.
- Is used to reset the complete system.
Page:
46
Version:
2014/11
Edition:
SL900 -OIM - USA
Default
Range
Standard
Standard, Alternative
Low
Low, Medium, High
Standard
Standard, Wide, High, Extended, Wide/High,
Wide/Extended, High/Extended, Wide/High/extended
After selecting a High model, the number of sensor pairs
1 to 5 must be chosen. After selecting an extended
model, the number of sensor pairs 1 to 4 must be chosen.
4
1..4 (Low security mode)
1
1 (Medium and High security mode)
All
All, Spare
8
1..20
3
1..20
3
1..20
Pulse open
Sensor open, Pulse open
On
On, Partial, Off
-
Service item: Indicates error state
-
Service item: Displays encoder data
-
Service item: Displays multibeam state
3
1..10
On
On, Off
Open doors
Open doors, Close doors
1xreturn/1xread
1x return signal / 1x read signal, 2x return signal
Normal
Normal, Special
Mitsubishi FR-D
Mitsubishi FR-D, Omron V7
-
Service item: Restore default settings
Default settings
OIM - Manual