6.3.2 External

Mains power.
The mains power is connected to the terminal strip located in the master unit.
Terminals are labelled L – N and the PE sign.
Fire alarm.
The fire alarm contact needs to be a N.C. (Normally Closed) contact.
It is connected directly to the microcontroller board
Fire alarm
Access control
Authorization pulses In and Out are connected directly to the microcontroller board.
Pulse In
Pulse Out
Return Signal In
Return Signal Out
Alarm contact can be connected to the relay's.
General alarm
Intruder alarm In
Intruder alarm Out
Page:
36
Version:
2014/11
Edition:
SL900 -OIM - USA
connector D – terminal 15 & 16.
connector F – terminal 16 & 17.
connector E – terminal 16 & 17.
connector F – terminal 11 & 12.
connector E – terminal 11 & 12.
Relay K0 – terminal 11 common, 12 N.C., 14 N.O.
Relay K1 – terminal 11 common, 12 N.C., 14 N.O.
Relay K2 – terminal 11 common, 12 N.C., 14 N.O.