Anchoring To The Floor; Anchoring With Mounting Plates - BOON EDAM Speedlane 900 Operation Installation And Maintenance

Table of Contents

Advertisement

5.5 Anchoring to the floor

The Speedlane 900 can be anchored directly to the floor.
Use the dimensions as shown in the Anchoring points drawing.
Drill the holes and anchore the Speedlane to the floor using 3/8" masonry anchors or 10mm wired
rods and chemical anchors.
Make sure that the Speedlane is level, if needed use shims to level the unit.

5.5.1 Anchoring with mounting plates

The Speedlane 900 can also be anchored using mounting plates.
The pictures below will also show a mounting template.
Mount the plates to the template.
Position the template at the exact place
with the marks on the centerlines
and check it with a level.
Drill the holes for the threaded ends or chemical anchors, using the templates.
The mounting in the floor must hold a load of 750 N for a single bolt.
Recommended:
Chemical anchors M10.
When chemical anchors are used,
drill the holes at least 90 mm deep in the floor.
Remove the template before mounting the frame.
Page:
30
Version:
2014/11
Edition:
SL900 -OIM - USA