6 Electrical wiring

Most wiring will come factory installed, only the external wiring and wiring between the master and
slave will need to be connected on site.

6.1 Wiring between the Master and Slave unit

The following cables run between the master and slave unit.
All cables are supplied from the factory.
1.
Motor cable
2.
Multi-beam cable
Multi beam for High model
Master – Slave connection
3.
- Motor encoder
- Authorization LED
- Traffic LED's

6.2 External wiring connection

1. Mains power.
2. Fire alarm contact.
3. Access control.
- Authorization pulse in and out.
- Return signals in and out.
- Alarm contacts.
4. Control panel.

6.3 Wire connection locations

6.3.1 Internal

Motor cable.
The motor in the slave unit will need to be connected directly to the frequency controller in the
master unit.
Multi-beam.
The multi-beam cable runs from the master unit to the slave unit.
With a high unit the cables will be marked with 1 and 2 and need to be connected to the
corresponding multi-beam transmitter.
Master – Slave connection.
The master – slave connection cable runs from the master unit to the slave unit.
It is connected to the terminal strip in the slave, wire number 1 to terminal 1, wire 2 to 2, etc.
Page:
35
Version:
2014/11
Edition:
SL900 -OIM - USA
Mentioned wiring is a general overview.
Please refer to project specific electrical drawings.
(4 x 0.75mm2 or 4 x 18 gauge)
(5 x 0.5mm2 or 8 x 20 gauge)
(5 x 0.5mm2 or 8 x 20 gauge)
(21 x 0.5mm2 or 21 x 20 gauge)
OIM - Manual