10.1 Boon Edam parameter settings

After a factory reset of the frequency inverter more parameters than given in the tables below must
be set to the default (BEBV) setting.
Please refer to the frequency inverter checklists in section 16.2.
Speedlane 900 Standard, High and Long types Boon Edam default parameters and range.
No.
Function
Pr.00
Start up boost [%]
Pr.01
Maximum speed [Hz]
Pr.02
Minimum speed [Hz]
Pr.03
Voltage Pr.19 @ Freq. [Hz]
Pr.19
Voltage @ Freq. Pr.03 [V]
Pr.125 Terminal 2 gain [Hz]
Speedlane 900 Wide Boon Edam default parameters and range.
NOTE!: The parameter settings for the Speedlane 900 Wide are for lanes which have a spring unit
installed.
No.
Function
Pr.00
Start up boost [%]
Pr.01
Maximum speed [Hz]
Pr.02
Minimum speed [Hz]
Pr.03
Voltage Pr.19 @ Freq. [Hz]
Pr.19
Voltage @ Freq. Pr.03 [V]
Pr.125 Terminal 2 gain [Hz]
* Settings higher than the default (Boon Edam) setting are only allowed when the measured
dynamic force is below 400N.
NOTE!: Changes to the Frequency Inverter settings only become effective when the power to the
unit has been switched off and on again.
NOTE!: Please refer to the Mitsubishi Frequency Inverter Instruction Manual for more details on
the parameters and their setting.
Page:
56
Version:
2014/11
Edition:
SL900 -OIM - USA
Default (BEBV)
Parameter default and setting range – Standard, High and Long
900-W&LW
Default (BEBV)
Parameter default and setting range – Wide
CAUTION!
After changing any of the parameter settings it should be ensured that the
Speedlane 900 is safe to operate and complies with the norms.
900&L
900&L
Setting range *
30
0-30
80
No range
5
No range
26
20-26
75
70-80
125
100-150
900-W&LW
Setting range *
30
0-30
80
No range
5
No range
26
20-26
75
70-80
100
No range
900-H&HL
900-H&HL
Default (BEBV)
Setting range *
30
0-30
80
No range
5
No range
26
20-26
75
70-80
125
100-150
900-HW&HLW
900-HW&HLW
Default (BEBV)
Setting range *
30
0-30
80
No range
5
No range
26
20-26
75
70-80
100
No range
OIM - Manual
Speedlane 900