14.5 Other errors

The table below shows a summary of other possible errors.
Problem
Door wings do not move.
Door turns slowly.
LED's blink red, doors are
closing and opening
continuously, alternated
with acoustic alarm
Door will not turn, no
acoustic alarm, traffic
signals and intruder alarm
work properly
Page:
69
Version:
2014/11
Edition:
SL900 -OIM - USA
WARNING!
Risk of personal injury or loss of life.
NOTE!
The material may be damaged or the operation of the door affected.
Cause
Supply voltage
Motor runs normally
Motor overheating
Motor not running
Defective Multibeam
FI setting
One of the two angle
encoders isn't
connected properly
Both angle encoders
aren't connected
properly
Solution
Check supply voltage and fuse.
Mechanical defect in transmission or slot.
Door runs too heavy and/or FI settings.
FOUT and VMAX values, replace the motor.
Check the Multibeam status.
Check the value of the parameters n011 to
n017.
Switch A and B signals of one angle encoder.
Check the encoder status in the menu.
Switch A and B signals of both angle encoders.
Check the encoder status in the menu.