Inspection and maintenance every 500 to 1000 hours or annually

Check the contactor

-
Open the electrical compartment cover (1).
-
Remove the cover (2).
-
Check contactor tips of starting contactor only and have
them renewed, if required.
Please contact your authorised distributor.
1
2
74

Change the wheel drive oil

ATTENTION
Folow the precautions for handling fluids and
lubricants.
NOTE
The wheel drivel oil needs to be changed only once after
1000 hours, further oil changes are required every 3000
hours (for procedure see 3000-hour inspection and main-
tenance).
e3362304
Check the electric cables, cable connectors
and connections for condition and tight-
ness
NOTE
Apply the handbrake and depress the emergency button
before every servicing.
-
Open the overhead guard to the 2nd lock-in position.
-
Electric motor terminals: Check the connectors for security
and traces of oxidation.
-
Check the battery cables for security.
-
Close the overhead guard and open the electrical com-
partment cover.
-
Check the wiring for chafing and security.
NOTE
Oxidized connections and broken cables lead to drops in
voltage causing malfunctions.
-
Eliminate any traces of oxidation and renew any broken
cables.
-
Close the electrical compartment cover.