168
Chapter 9—Component Guide Part II
BPF
A BPF (band-pass filter) attenuates signals above and below the specified center fre-
quency while allowing a band of signals around that frequency to pass through unaf-
fected.
The BPF control window features INPUT, filter, and OUTPUT sections.
The BPF component parameters are explained in the following table.
Section
ON/OFF
INPUT
Filter
OUTPUT LEVEL
MUTE
DME32—Owner's Manual
The BPF component features one input and one output.
Parameter
ON/OFF
LEVEL
–Infinity dB to 0.0 dB
PHASE
NOR/REV
FREQ
20.0 Hz–20.0 kHz
Q
10–0.10
–Infinity dB to 0.0 dB
ON/OFF
Range
Turns the component on and off
Adjusts the input signal level
Inverts the input signal
Adjusts the BPF center frequency
Adjusts the filter's selectivity
Adjusts the output signal level
Mutes the output
Description