114
Chapter 8—Component Guide Part I
The Delay parameters for all channels are explained in the following table.
Section
LOW,
LOW-MID,
HIGH-MID,
HIGH
DELAY SCALE
1. This control's label depends on the Delay Scale setting.
In the DELAY SCALE section, "FS" indicates the selected wordclock frequency, and
"340 m/s" and "1,115.5 ft/s" are the speed of sound in meters and feet respectively (air
temperature = 14˚C, 57.2˚F).
The parameter ranges for the Sample, m, and feet settings are as follows:
Samples
Meters
Feet
Cross
The CROSS page features the 4-way crossover controls and crossover graph.
Note that the Gc controls (not shown here) appear only when an Adjustable Gc type
SLOPE & TYPE filter is selected.
The crossover graph at the top of the window displays the crossover settings graphically.
A vertical dotted line indicates the crossover frequency of each channel: "L" for low,
"ML" for low-mid, "MH" for high-mid, and "H" for high.
DME32—Owner's Manual
Parameter
Range
ms
0.0–500.0 ms
See the following
1
Sample
table
ON/OFF
ON/OFF
See the following
table
Delay Scale
Description
Sets the delay time in milliseconds
(linked to control below)
Sets the delay time in the units chosen
using the DELAY SCALE buttons (linked
to ms control)
Turns the delay on and off
Selects the delay units for the Sample
controls
FS = 48 KHz
0–24000 samples
0–22050 samples
0.0–170.0 meters
0.0–557.8 feet
FS = 44.1 kHz