62
Chapter 5—Building Configurations
Sending Configurations to the DME32
This section explains how to send the current configuration to the DME32. Configura-
tions must be compiled before they can be sent. See "Compiling Configurations" on
page 61. When a configuration is sent to the DME32, all its scenes are sent as well.
Note: When a configuration is sent to the DME32, sound may be output suddenly,
depending on the system, so turn down the D/A converters or power amps beforehand.
Choose Data Transfer from the File menu.
1
The Data Transfer window appears, as shown below.
In the Mode section, click Send.
2
From the List, select the DME32 configuration memory to which you want
3
to send the configuration.
The List shows the titles of the configurations already stored in the DME32. The title of
the current configuration has a green indicator next to it. If no data is stored in a mem-
ory, the title "NO DATA" is displayed.
In the Title field, enter a title for the configuration.
4
Titles can be up to 24 characters long, although only the first seven characters appear
on the DME32 display.
Click Execute.
5
If you selected a DME32 configuration memory that already contains data, an over-
write confirmation message appears. Click OK to overwrite and proceed with the trans-
fer, or click Cancel to cancel the operation.
The current configuration is sent to the DME32 and the configuration transfer progress
indicator appears, as shown below.
When the transfer is complete, the transfer progress indicator closes.
If the message "Memory Full" appears, the configuration cannot be transferred.
Click Cancel to close the Data Transfer window.
6
The Data Transfer window closes.
DME32—Owner's Manual