218
Chapter 11—GPI Interface
The GPI OUT parameters are explained in the following table.
GPI Select
Scene Change Scene Select
Parameter
Threshold
Value
1. Components in the current configuration can be selected.
2. Depends on the component selected.
3. Depends on the parameter selected.
The following illustration shows GPI OUT terminals in the low and high conditions.
GPI settings are stored in configurations.

Scene Recall

When GPI outputs are assigned to scenes, the OUT terminal switches between low and
high in accordance with the Threshold Value and Terminal button setting, as shown in
the following table.
High = +5 V
Threshold Value
Low-to-high
High-to-low
DME32—Owner's Manual
Section
Parameter
UNIT
GPI CH
COMPONENT
PARAMETER
Level control
Terminal
buttons
GPI connection
OUT
GND
0 V
(Low)
Low = 0 V
Range
1–4
Selects a DME32
1–16
Selects a GPI output
1–99
Assigns a scene to the selected GPI output
Selects the component whose parameter is
1
to be assigned
2
Selects the parameter to be assigned
Sets the transition point at which the GPI
3
output switches
Low-to-high
High-to-low
Scene recalls
Before recall
OUT = low
OUT = high
Description
GPI connection
OUT
GND
+5 V
(High)
After recall
OUT = high
OUT = low

Hide quick links: