Section 4. Operation

Introduction

Once you have installed the power supply and have connected both the AC input
power and the load as covered in
operate.

Operating Modes

Your power supply has two basic operating modes: Constant Voltage Mode and
Constant Current Mode. The mode in which the power supply operates at any given
time depends on the combination of:
Figure 4.1
Figure 4.1 Operating Modes
Release 2.2
Operating
Modes, below, offers a brief explanation of Constant Voltage and
Constant Current Mode operation.
"Connecting Multiple Supplies in Series (Voltage Mode Only)" on page
covers using multiple supplies.
output voltage setting V
output current limit setting I
resistance or impedance of the attached load R
represents the relationships between these variables.
Output
Voltage
Constant Voltage
Mode Region
V SET
O
O
Section 2
Installation, the power supply is ready to
SET
SET
>
R
V
L
SET
I
SET
R
Crossover Point
R
Constant Current
Mode Region
Output
Current
I SET
L
=
V
L
SET
I
SET
<
V
L
SET
I
Where:
SET
R
= Load Resistance
L
V
= Output Voltage Setting
SET
I
= Output Current Setting
SET