Task 14: Perform Initial DEFINITY AUDIX Administration
The system displays the Voice Group Status screen.
5. Make sure all the ports that are supposed to be active are shown on the
screen with the correct location and extension and that the State field
shows ISI (In-Service Idle).
6. If any of the port information is incorrect, see DEFINITY AUDIX
System — Maintenance book, 585-300-110 for complete troubleshooting
procedures.
Step 7 is required only if the DEFINITY AUDIX system will use CL integration. If
not, skip to step 8.
7. Type status switch-link and enter
switch link set up in Task 14E: Set Switch-Link Parameters. The screen
should show the state field as ISB and the DCIU Switches that are
administered should show I in the DCIU Switches field. If the values on the
screen differ from the values just given, see DEFINITY AUDIX System —
Maintenance book, 585-300-110 for complete troubleshooting
procedures.
8. Proceed to Task 15: Activate Parameters and Basic Features.
to check the status of the
RETURN
Issue 2 December 1996
3-29