Software Upgrade
Confirm that the board diagnostics passed.
!
WARNING:
In the next step do not press 1 (the Initialize Disk option), which would
destroy all existing customer data.
14. [10 min]
When the menu appears, enter 3 to select Copy Generic Partitions To
Disk. The system responds with information on the screen similar to what
follows:
Enter option: 3
Enter SCSI ID of Disk (default 0):
15. Enter 0 (zero, the default) for the SCSI ID. Wait for copying to complete
(several rows of dots and messages will appear as copying progresses).
After the generic partitions are copied, the system automatically reboots.
The system scrolls with information similar to what follows:
Enter SCSI ID of Disk (default 0): 0
Copy generic data from tape to disk
..........
The following line appears for upgrades if the hard disk drive is larger
than 6 hours:
Changing <var.s5> partition size from (e.g.) 35152 to (and always
ends at) 17576
Copy Generic Partitions PASSED
Automatic reboot
Loader or Utility Abort
Board Diagnostics PASSED
Transferring To Software
Booting the Operating System... OS loaded. Transferring control...
MFB 386 FW Version:AU00S0EF
Local Console: Output on, Input off
Remote Maintenance Console: Inactive
MFB Board Diagnostics: Passed
Transferring t
Booting the OS
total real memory = 15728640
total available memory = 14032896
AT&T UNIX System V/386 Release 4.0 Version 2.1
o Software
Issue 2 December 1996
7-17