500 H - ROUTINE SERVICING - EVERY 500 HOURS OF SERVICE OR 1 YEAR
CHECK
MANITOU offers a hydraulic oil analysis kit which makes it possible to extend the
recommended interval for the periodic service (2,000 hours).
In this case, we recommend an analysis of the hydraulic oil every 500 hours of service.
This analysis kit makes it possible to confirm the oil quality to reach the deadline of
2,000 hours.
- Order an oil analysis kit from your dealer.
- On receipt of the kit, take a sample and follow the detailed instructions.
- According to the results, keep the analysis report or replace the hydraulic oil.
NOTE: This kit is highly recommended for specific uses causing stresses on the
hydraulic circuit:
• Extreme environmental conditions,
• Use of attachments with a very high hydraulic flow rate (sweepers, mixers, etc.).
GREASE
- Wipe the mast lifting chains with a clean, lint-free cloth
- Vigorously brush the chains to get rid of any foreign matter, with a hard nylon
brush and clean diesel fuel.
- Rinse the chains by means of a paint brush impregnated with clean diesel fuel and
dry them with a compressed air jet.
- Carefully check each chain for any signs of wear.
In case of technical faults, consult your dealer.
- Grease the chains sparingly (
LUBRICATE
DISMANTLING LEFT-HAND DOOR CASING
- Remove the tip of the lever 1.
- Remove the protective casing 2 of each lock.
DISMANTLING RIGHT-HAND DOOR CASING
- Remove the tip of the lever 3.
- Unscrew the tip 4 of the opening control for the right-hand half-door
- Remove the protective casing 5 of each lock.
MANITOU oil analysis kit Part No. 958162.
IMPORTANT
LUBRICANTS AND FUEL).
Hydraulic oil
Mast lifting chains
Cab door locks (option)
3 - 20
www.duma-rent.com
2
1
5
3
4