Custom Pause Sensors

When a weather condition becomes true, a Custom Pause sensor will
stop irrigation and also stop the irrigation timer. When the condition
becomes false again, irrigation will start exactly where it left off.
For example, if a station is set to irrigate for 20 minutes but is shut
down by a Pause sensor after only 5 minutes; when the weather
condition becomes false again and after Resume, that station will
receive the full remaining 15 minutes of irrigation left on the timer.

Custom Prevent Sensors

When a weather condition becomes true, a Custom Prevent sensor
will stop irrigation but allow the irrigation timer to continue to run.
Then when the condition becomes false again, irrigation will resume
at the same time had the weather condition never occurred.
For example, if a station is set to irrigate for 20 minutes but is shut
down by a Prevent sensor after only 5 minutes, if the condition
becomes false again after 10 minutes then that station will only
receive the remaining 5 minutes of irrigation left on the timer.

Local Weather Sensor

Both the LX-IVM and IVM Pro support one local weather sensor. See
"Connect Local Weather Sensors" on page 48 for more details.
28
ESP-LXIVM Series Controllers

Station Setup

Station Setup tells the ESP-LXIVM controller how many and what
type of stations are used by your irrigation system.
B
NOTE: Before setting up stations, follow the previous instruc-
tions to set up master valves and weather sensors (if present).
Turn the dial to 2-Wire Settings
A
At the 2-WIRE SETUP screen, press the Down Arrow key to select
Station Setup, then press Next.
B
At the Station Setup screen, press the + and – keys to set the
desired Station from 1 to 60 (240 for LX-IVM Pro), then press the
Right Arrow key.
A
2-WIRE SETUP
Master Valves
Weather Sensors
Station Setup
Flow Sensors
Advanced Station Settings
Next
B
Station Setup
- - - - -
001
STA
Address