Alarm Conditions

Turn the controller dial to AUTO
A
When an alarm condition is present, the Alarm key label will be
present on screen. Press the Alarm key to view alarm details.
B
Any present alarm conditions will then be shown. Press the More
key to continue to the next page.
A
Auto
Sat
06:00
AM
13 Jan 2018
Alarm
B
NOTE: Take the appropriate action to address each alarm condi-
tion. When all alarms have been addressed, the alarm light on
the front panel will no longer be illuminated.
22
ESP-LXIVM Series Controllers
B
No Water Days
No Run Times
No Start Times
No PGM will AUTO run
More
Exit

List of Alarm Conditions

Alarm
No Water Days
There are no water days set in any program.
No Run Times
There are no run times set in any program.
No Start Times
There are no star times set in any program.
No PGM will AUTO
There is no program with start times and run
Run
times and water days.
Max PGMs Stacked
Max is 8 (equal to the start times).
Flow Alarm
Shows for high or low flow conditions. See
"Flow Alarms" on page 63 for more details.
Zero Learned Flow
0 flow is learned for 1 or more stations
FloWatch is turned on. See "Set Flo-Man-
ager®" on page 83 for more details.
No Two-Wire Mod-
2-Wire Module is not enumerated.
ule
Invalid Module
One or more of the following in is installed:
Installed
Triac Module, ESPLX-SM75 Module, FSM
Module, FSCM Module, ESP-LXD-M50 Mod-
ule.
All Addresses are
There is no address assigned for any of the
Zero
four device types.
All paths turned off
All 2-Wire paths have been turned off by the
user (remote or at controller).
No AC power
The panel is running on the 9V battery (no
AC).
Duplicate addressee Shows if there are any duplicate addresses
for a Station, MV, Weather, or Flow device.
Shows up to two duplicates.
Device not
Shows if a device is addressed but not
responding
responding to ping.
Shorted paths
One or more paths have been automatically
turned off due a short being detected.
Condition