Connect Custom Wiring (optional)

EN
If desired, the provided 230 volt power cord can be
removed and replaced with a custom wiring.
DO NOT plug in the transformer or connect external power until you
have completed and checked all wiring connections.
Electric shock can cause severe injury or death. Make sure power
supply is turned OFF before connecting power wires.
A
Locate the transformer wiring compartment in
the lower left corner of the controller unit. Use a
screwdriver to remove the cover and expose the
transformer connection wires.
B
Route the three external power source wires
through the conduit opening at the bottom of
the unit and into the wiring compartment.
C
Connect the external power source wires (two
power and one ground) to the transformer
connection wires inside the wiring compartment.
Ground wire must be connected to provide electrical surge protection.
Permanently mounted conduit shall be used for connecting main
voltage to the controller

NOTE: Use either the provided wire nuts or the
installed connector for this step.

Controls and Indicators

Turn the dial to select programming features.
OFF
Disables automatic
irrigation.
MANUAL STATION
Start watering
any or all stations
immediately.
SEASONAL ADJUST
Adjust Run Times from
5% up to 200%.
SENSOR
Set controller to obey or
ignore a rain sensor.
6
ESP-TM2 Controller

WARNING

WARNING

WARNING
AUTO RUN
Watering occurs
automatically.
RUN DAYS
Set watering day
options for each
program.
D
Verify that all wiring connections are secure,
then replace the wiring compartment cover and
secure it with the screw.
A
B
DO NOT apply power until you have completed and checked all wiring
connections.
Brown supply wire (hot) to the brown transformer wire labeled with "L"
Blue supply wire (neutral) to the blue transformer wire labeled with "N"
Green-with-yellow-stripe supply wire (ground) to the green-with-yel-
low-stripe transformer wire
DATE/TIME
Set the current Date
and Time.
RUN TIMES
START TIMES
Set Run Times for
Set up to 4 Start Times
each program.
C
TO EXTERNAL
POWER SUPPLY

WARNING
POWER WIRING CONNECTIONS
230 VAC (International)
PROGRAM SELECT
BUTTON
Select Program A, B
or C.
– / + BUTTONS
Adjust program
settings.
BACK/NEXT
BUTTONS
Select
programming
options.
per program.