Flow Alarms
The LX-IVM controller can be set up to issue alarms when flow condi-
tions are in excess of your High Flow settings or below your Low Flow
settings.
Occasionally a flow condition will be detected If the controller is set
up to issue alarms for these conditions, the alarm light will illumi-
nate and detailed descriptions of the Flow Alarm conditions will be
created.
Station Flow Alarms
Turn the controller dial to Alarms/History
63
ESP-LXIVM Series Controllers
A
At the ALARMS AND HISTORY screen, press the Down Arrow key
to select Flow Alarms, then press Next.
B
At the Flow Alarms screen, with Station Flow Alarms selected,
press Next.
A
ALARMS AND HISTORY
Flow History
Flow Alarms
Electrical History
Next
C
The Station Flow Alarms screen appears, showing the first station
where there is an alarm. Press the + and – keys to view the next
Station Flow Alarm.
C
Station Flow Alarms
Station:
001
Alarm:
High Flow
FloZone:
FZ-1
Flow Rate: 122.6 GPM
Time:
04:02 AM
Date:
09-Oct-2010
Back Next
Note each station which has an alarm, then see "Clear Flow Alarms"
on page 65 for more details on how to clear flow alarms.
B
Flow Alarms
Station Flow Alarms
FloZone Flow Alarms
Clear Flow Arms
Next