Set Priority - Rain Bird ESP-LXIVM Series Installation, Programming & Operation Manual

Hide thumbs Also See for ESP-LXIVM Series:
Table of Contents

Advertisement

C
Press the + and – keys to set the desired Station Address. Press
the Arrow keys to navigate between the number setting fields.
Once all fields are entered, press the Next key.
B
NOTE: An alarm will show if a duplicate 2-Wire Device address
is entered for more than one sensor. See "Alarms" on page 21
for more details.
C
Station Setup
001
1 0 0 0 1
1
STA
Address
Next
29
ESP-LXIVM Series Controllers

Set Priority

Each station can be set to high, medium, low or Non-irrigation.
The controller will run all high priority stations first, then all medium
and finally all low priority, regardless of the station's program set-
tings.
A
At the Station Setup screen, with Set Priority selected, press Next
to continue.
B
NOTE: Station Priorities are only used when Station Sequenc-
ing is set to Sequence by Station Priority. If you're using the
default Sequence by Station Numbers, then skip the next
step by pressing Next.
B
Press the + and – keys to select the priority type. Each station can
be set to High, Medium, Low or Non-irrigation.
B
NOTE: Non-irrigation stations such as fountains and land-
scape lighting receive priority to always run, regardless of
weather conditions.
A
Station Setup
STA
001
Set Priority
FloZones
Weather Sensors
Next
B
Station Setup
STA
001
Priority:
High
Done

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents