Station Sequencing

Allows you to optimize water windows by controlling the sequence in
which stations can run.
Choose from 2 methods:
Sequence by Station Number - (system default).
1.
Sequence by Station Priority - required when using Flo-Manager®
2.
(LX-IVM Pro only). This option decreases the overall time required
to complete watering when operating multiple stations simultane-
ously.

Station Sequencing by Station Number (Default)

Stations will operate in the following order:
LX-IVM has a capacity of 60 stations.
1 Station
number
LX-IVM Pro has a capacity of up to 240 Stations.
LX-IVM has 10 independent Programs available.
2 Program
assignment
LX-IVM Pro has 40 independent Programs available.
NOTICE
Non-irrigation priority stations will always be selected to oper-
ate first.
38
ESP-LXIVM Series Controllers

Station Sequencing by Station Priority

Stations will operate in the following order:
Station
1
Non-Irrigation > High > Medium > Low
priority
Station run
2
Longest run time > shortest run time
time
LX-IVM has a capacity of 60 stations.
Station
3
number
LX-IVM Pro has a capacity of up to 240 Stations.
LX-IVM has 10 independent Programs available.
Program
4
assignment
LX-IVM Pro has 40 independent Programs available.
NOTICE
If Flo-Manager® (LX-IVM Pro only) is turned ON, then the
default Station Sequencing setting is Sequence by Station
Priorities. To select Station Sequencing by Station Number,
Flo-Manager® must first be turned OFF. See "Set Flo-Man-
ager®" on page 83 for more details.