Test Shorted Paths - Rain Bird ESP-LXIVM Series Installation, Programming & Operation Manual

Hide thumbs Also See for ESP-LXIVM Series:
Table of Contents

Advertisement

Test Shorted Paths

The ESP-LXIVM controller can quickly determine if faults are present
on the 2-Wire path.
Although finding the exact location of issues in the field often
requires some amount of in-the-field troubleshooting with a clamp
meter, the controller has some built-in features to help you narrow
down the possible issues.
Before beginning 2-Wire diagnostics, it may be helpful to take the
following steps to eliminate possible other causes:
• Review Station Priorities: The LX-IVM controller can be config-
ured to irrigate based on the station priorities. If multiple pro-
grams are running, higher priority stations will irrigate prior to
medium priority stations, and medium priority stations will irri-
gate prior to lower priority stations. See "Set Priority" on page
29 for more details.
• Run Test All Stations: The Test All Stations manual test will take
priority above pre-programmed irrigation and allow you to deter-
mine which stations are working properly. See "Test All Stations"
on page 101 for more details.
Turn the controller dial to Diagnostics
53
ESP-LXIVM Series Controllers
A
At the DIAGNOSTICS screen, press the Down Arrow key to select
Diagnostics, then press Next.
B
At the second DIAGNOSTICS screen, press the Down Arrow key to
select Test Shorted Paths, then press Next.
A
DIAGNOSTICS
Test All Stations
Diagnostics
Confirm Programming
Next
C
At the SELECT PATH TO ENERGIZE FOR TESTING screen, press
the Down Arrow key to select the desired path for testing, then
press Next.
D
Press and hold the YES key to energize the current path for test-
ing.
C
SELECT PATH TO
ENERGIZE FOR TESTING
Path 1
OK
Path 2
OK
Path 3
OK
Path 4
OK
Next
H
Repeat this process to test other PATHS as desired.
B
DIAGNOSTICS
List Not Responding
List Responding
Ping Valve/Sensor
Test Shorted Paths
Controller Output
Next
D
Hold Yes to energize
Path 1 for testing
in the field.
Note: Irrigation will
be disabled.
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents