Set Flow Limits

SEEF (High Flow) and SELF (Low Flow) Settings and
Actions
To most effectively use FloWatch™, you will want to first set your
High Flow and Low Flow thresholds and actions. SEEF (High Flow)
stands for Seek and Eliminate Excessive Flow and deals with how
you want the controller to respond when excessive flow is occurring,
as might be the case with a mainline break or a valve which is stuck
in the open position. SELF (Low Flow) stands for Seek and Eliminate
Low Flow and deals with what the controller should do when low
flow is present, as might be the case during a pump failure, munici-
pal water supply issue or when a valve fails to open.

Set Up and Configure High Flow and Low Flow

Turn the controller dial to Flow Sensor
86
ESP-LXIVM Series Controllers
A
At the FLOW SENSOR screen, press the Down Arrow key to select
Set FloWatch, then press Next.
B
At the FloWatch screen, press the Down Arrow key to select Set
Flow Limit, then press Next.
A
FLOW SENSOR
Set Flow Rates
Set FloManager
Set FloWatch
Current Flow Reading
Set Flow Units
Next
C
At the High Flow Settings screen, press the + and – keys to set the
desired High Flow Threshold percentage (Max. 200%). Then press
the Down Arrow key.
D
Press the + and – keys to set the desired High Flow settling time
(Up to 10 minutes ), then press Next.
• Press and HOLD keys to accelerate settings.
C
High Flow Settings
High Flow
130
%
Threshold
Settling
01 Mins
Time
Next
B
FloWatch
FloWatch On/Off
Set Flow Limits
Set Flow Actions
Next
D
High Flow Settings
High Flow
130 %
Threshold
Settling
05
05 Mins
Time
Next