Set Flow Actions - Rain Bird ESP-LXIVM Series Installation, Programming & Operation Manual

Hide thumbs Also See for ESP-LXIVM Series:
Table of Contents

Advertisement

E
At the Low Flow Settings screen, press the + and – keys to set the
desired Low Flow Threshold percentage (Max. 95%). Then press
the Down Arrow key.
F
Press the + and – keys to set the desired Low Flow settling time
(Up to 10 minutes ).
• Press and HOLD keys to accelerate settings.
E
Low Flow Settings
Low Flow
070
%
Threshold
Settling
01 Mins
Time
Done
87
ESP-LXIVM Series Controllers
F
Low Flow Settings
Low Flow
070 %
Threshold
Settling
03
01 Mins
Time
Done

Set Flow Actions

There are 3 options available to Set Flow Actions during High or Low
flow:
1.
Diagnose & Eliminate
Shut Down & Alarm
2.
Alarm Only
3.
Turn the controller dial to Flow Sensor
A
At the FLOW SENSOR screen, press the Down Arrow key to select
Set FloWatch™, then press Next.
B
At the FloWatch screen, press the Down Arrow key to select Set
Flow Actions, then press Next.
A
FLOW SENSOR
Set Flow Rates
Set FloManager
Set FloWatch
Current Flow Reading
Set Flow Units
Next
B
FloWatch
FloWatch On/Off
Set Flow Limits
Set Flow Actions
Next