Xilinx KCU116 User Manual page 45

Table of Contents

Advertisement

Table 3‐11:
zSFP0‐ zSFP3 Module Control and Status Connections (Cont'd)
zSFP Control/
Status Signal
SFP_TX_FAULT
SFP_TX_DISABLE
SFP_MOD_DETECT
(1)(2)
SFP_RS0
(1)(2)
SFP_RS1
SFP_LOS
Notes:
1. The RS0/RS1 PU/PD resistors are not populated. There are pull-down resistors built into the SFP/zSFP modules that select
the lower bandwidth mode of the module.
2. Also available via I2C control. For this and additional information about the enhanced SFP+ module, see the SFF-8431
specification at the SFF-8431 specification website
KCU116 Board User Guide
UG1239 (v1.2) September 28, 2018
Board Connection
High = Fault
Test Point J65
Low = Normal operation
Off = SFP Disabled
Jumper J54
On = SFP Enabled
High = Module not present
Test Point J66
Low = Module present
PU R182 = Full RX bandwidth
PU R589/ PD R605
PD R190 = Reduced RX bandwidth
PU R185 = Full RX bandwidth
PU R590/ PD R606
PD R202 = Reduced RX bandwidth
High = Loss of receiver signal
Test Point J67
Low = Normal operation
[Ref
www.xilinx.com
Chapter 3: Board Component Descriptions
29].
SFP Module
zSFP3 J6
45
Send Feedback

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents