Siemens SINUMERIK 840D sl Function Manual page 1087

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Description of formal parameters SINUMERIK 810D, 840D
The table below lists all formal parameters of the RUN_UP function for 810D, 840D:
Signal
MCPNum
MCP1In
MCP2In
MCP1Out
MCP2Out
MCP1StatSend
MCP2StatSend
MCP1StatRec
MCP2StatRec
MCP1BusAdr
MCP2BusAdr
MCP1Cycl
MCP2Cycl
MCPMPI
MCP1Stop
MCP2Stop
MCP1NotSend
MCP2NotSend
MCPSDB210
MCPCopyDB77
MCPBusType
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
I/O
Type
Value range
I
INT
0 to 2
I
POINTER
I0.0 to I120.0 or F0.0
to F248.0 or DBn
DBX0.0 to DBXm.0
I
POINTER
Q0.0 to Q120.0 or
F0.0 to F248.0 or
DBn DBX0.0 to
DBXm.0
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
I
POINTER
Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
I
INT
1...15
I
S5time
Recommendation:
200 ms
I
BOOL
I
BOOL
I
BOOL
I
BOOL
I
BOOL
I
BYTE
Detailed description
2.12 Block descriptions
Remark
Number of active MCPs
0: No MCP installed
Start address for input
signals of relevant machine
control panel
Start address for output
signals of relevant machine
control panel
Start address for status double
word for data transmission to the
machine control panel:
DW#16#08000000: Time-out,
otherwise 0
Start address for status double
word for data reception by machine
control panel:
DW#16#00000400: Time-out,
otherwise 0
Bus address of machine control
panel
Time reference for cyclic updating
of signals to machine control panel
1: All machine control panels
connected to the MPI bus
(without GD parameterization)
0: Start transfer of machine control
panel signals
1: Stop transfer of machine control
panel signals
0: Send and receive operation
activated
1: Receive machine control panel
signals only
0: No SDB 210 for MCP
1: Activate timeout monitors on
SDB 210 for MCP
1: Copy between DB 77 and MCP
pointers on DB 7
Can only be used with standard
SDB 210 configuration on DB 77.
0: MPI or OPI
b#16#33: PROFIBUS for
MCP1 and MCP2
b#16#55: MSTT (i.e. Ethernet)
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all