Error identifiers
If it was not possible to execute a job, the failure is indicated by "logic 1" on status parameter
error. The error cause is coded at the block output State:
State
WORD H
1 to 8
0
0
1 to 8
0
0
1 to 8
0
1 to 8
0
0
Configuration steps
To write NC variables, the same configuration steps are required as for reading NC
variables. It is useful to store the address data of all NC variables to be read or written in a
DB.
Basic logic functions: PLC Basic program powerline (P3 pl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Meaning
WORD L
1
Access error
2
Error in job
3
Negative acknowledgment, job
not executable
4
Data areas or data types do
not match or string is empty
6
FIFO full
7
Option not set
8
Incorrect target area (SD)
9
Transmission occupied
10
Error in variable addressing
11
Variable addr. invalid or var. is
read-only
12
NumVar = 0
Detailed description
2.12 Block descriptions
Note
In high byte number of Var in which
error occurred
Incorrect compilation of Var in a job
Internal error, any help:
NC RESET
Check data to be written in SD1 to SD8;
in high byte number of the Var in which
error occurred
Job must be repeated since queue is
full
BP parameter "NCKomm" is not set
SD1 to SD8 may not be local data
Job must be repeated
Unit or column/line contains value 0
Check Addr (or variable name), area,
unit
Check parameter NumVar