Characteristics - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

DC link components
7.1 Control Supply Module CSM
6SL3100-1DE22-0AA1
Ventilation clearances,
above/below
Weight
Above 40° C, a linear derating of the output current above a 26 V output voltage and higher must be observed
1)
When using circuit breakers for protection, UL approval is only possible in TN/TT line systems with grounded neutral
2)
point. Conventional fuses are required for UL approval in line supplies with grounded line conductor.
The specified circuit breakers are approved for UL and IEC. For applications according to IEC, equivalent circuit break-
ers and fuses are permissible. The specified Class fuses are not approved for IEC.
7.1.8.1

Characteristics

Derating characteristic
For ambient temperatures > 40 °C, a linear derating for the output current must be observed
as of 26 output voltage.
Figure 7-6
164
Unit
Value
mm
≥ 80
kg
4.8
Current derating for ambient temperatures >40 °C as a function of the output voltage
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7