Replacing The Fan; Safety Instructions When Replacing A Fan; Replacing The Internal Fan On The S120 Combi Power Module - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Service and maintenance

13.2 Replacing the fan

13.2
Replacing the fan
13.2.1

Safety instructions when replacing a fan

Electric shock due to applied voltage or residual charge
Switch off the power supply (400 VAC) before replacing the fan.
A hazardous voltage is still present for up to 5 minutes after the power supply has been
switched off.
Contact with live parts can result in death or serious injury.
• Remove the device cover or the fan cover only after 5 minutes have elapsed.
• Check for zero voltage before removing the component.
Electric shock when live parts are touched during fan replacement
Contact with live parts while the fan is being replaced can result in death or serious injury.
• When removing the fan, you must observe the ESD regulations.
• Assign qualified personnel to install spare parts.
13.2.2

Replacing the Internal fan on the S120 Combi Power Module

When required, the internal S120 Combi fan can be replaced. It can be ordered as a spare
part (Article number: 6SL3161-0JP00-0AA0).
Removing the internal fan
1. Remove the S120 Combi front plate (see Section "Electrical connection of Motor Modules
and DC-link components (Page 181)")
306
WARNING
WARNING
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7