Selecting Power Supply Units - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Cabinet design and EMC
12.4 24 V DC supply
12.4.5

Selecting power supply units

You are advised to use the devices in the following table. These devices meet the applicable
requirements of EN 60204-1.
Table 12- 4
Recommended SITOP Power
Rated output cur-
Phases
rent [A]
5
1 / 2
10
1 / 2
20
1 / 2
3
40
1 / 2
3
Note
When using an external 24 V power supply with a continuous current > 20 A, an overcurrent
protection device must be used for the S120 Combi Power Module, the cables and the
busbars. A circuit breaker is recommended as overcurrent protection device.
The tripping characteristic of the circuit breaker depends on the following:
• the loads to be protected
• The maximum current provided by the power supply unit in the case of a short-circuit.
Table 12- 5
Recommendation for Control Supply Module
Rated output cur-
Phases
rent [A]
20
3
282
Rated input voltage [V]
Working voltage range [V]
AC 120 ... 230 / 230 ... 500
85 ... 264 / 176 ... 550
AC 120 ... 230 / 230 ... 500
85 ... 264 / 176 ... 550
AC 120 / 230
85 ... 132 / 176 ... 264
3 AC 230 / 400 ... 288 / 500
320 ... 550
AC 120 / 230
85 ... 132 / 176 ... 264
3-ph. 230/400 to 288/500
320 - 550 AC
Input voltage range [V]
AC 380 - 10 % (- 15 % < 1 min)
... AC 480 + 10 %
DC 300 ... 800
Short-circuit current [A]
Approx. 5.5 (power up)
Typ. 15 for 25 ms (opera-
tion)
Approx. 12 (power up)
Typ. 30 for 25 ms (opera-
tion)
Approx. 23 (power up)
Typ. 60 for 25 ms (opera-
tion)
Approx. 46 (power up)
Typ. 120 for 25 ms (opera-
tion)
Short-circuit current [A]
< 24
Manual, 11/2017, 6SL3097-4AV00-0BP7
Article number
6EP1333-3BA00-8AC0
6EP1334-3BA00-8AB0
6EP1336-3BA00-8AA0
6EP1436-3BA00-8AA0
6EP1337-3BA00-8AA0
6EP1437-3BA00-8AA0
Article number
6SL3100-1DE22-0AA.
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents