Installation; Technical Data - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
9.3.5

Installation

Figure 9-11
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is
bare, unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Mount the DME20 DRIVE-CLiQ Hub Module External on the contact surface. The
tightening torque is 6.0 Nm.
9.3.6

Technical data

Table 9- 23
6SL3055-0AA00-6AB.
Electronics power supply
Voltage
Current (without DRIVE-CLiQ node)
PE/ground connection
Weight
222
Contact surface
Mounting dimensions DME20
Technical data of the DME20
Unit
V
DC
A
DC
Screwed to the housing M5
kg
Manual, 11/2017, 6SL3097-4AV00-0BP7
Value
24 (20.4 ... 28.8)
0.15
0.8
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents