Accessories; Drive-Cliq Cabinet Bushing; Description - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Accessories

11.1

DRIVE-CLiQ cabinet bushing

11.1.1

Description

A DRIVE-CLiQ cabinet bushing is used to connect the DRIVE-CLiQ cables between the
inside and outside of the control cabinet. It is used in a control cabinet panel. The data lines
and the voltage supply contacts of the DRIVE-CLiQ are also routed through the bushing. The
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ cables is available with DRIVE-CLiQ
connector and M12 connector/socket.
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ connectors
The cabinet bushing has degree of protection IP54 according to IEC 60529 from the outside
towards the inside. Inside the control cabinet, a connection is established according to
degree of protection IP20 or IPXXB acc. to IEC 60529. So that the complete outside of the
cabinet bushing, including the DRIVE-CLiQ interface, has degree of protection IP54, a
DRIVE-CLiQ cable must be used, which as a minimum must also have degree of protection
IP54.
DRIVE-CLiQ cabinet bushing for M12 connector/socket
The cabinet bushing has degree of protection IP67 according to IEC 60529 from the outside
towards the inside. Inside the cabinet a connection according to degree of protection IP67 in
compliance with IEC 60529 is realized.
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
11
263